Eaton Powerware 9355 Installation Manual

  1. Eaton 9355 Ups Installation Manual
Also See for 9355

Porta tool vw line bore measuring instruments. Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality i. Table of Contents.

User manual - 120 pages
Installation and operation manual - 100 pages
Installation manual - 36 pages
123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100
9355 UPS
20/30 kVA

Advertisement

Eaton powerware 9355 batteries

Also See for Eaton 9355

Eaton E.T.N 1500 VA - 60kVa Reference Manual120 pages

Eaton 9355 Ups Installation Manual

Related Manuals for Eaton 9355

  • UPS Eaton 9355 User Manual
    10/15 kva (90 pages)
  • UPS Eaton 9355 User Manual
    Powerware series parallel ups 10/15 kva (78 pages)
  • UPS Eaton UPS 20 User Manual
    Ups 20 - 40 kva, 230/400 v 50/60 hz output (3-phase input/output) (56 pages)
  • UPS Eaton 9355 Installation Manual
    Powerware series tie cabinet for use with eaton 9355 20/30 kva upss (36 pages)
  • UPS Eaton Eaton series Instructions Manual
    Battery upgrade instructions (14 pages)
  • UPS Eaton 9390 Brochure & Specs
    20-160 kva (20 pages)
  • UPS Eaton 9390 Installation And Operation Manual
    40–80 kva ups, integrated distribution cabinet (100 pages)

Summary of Contents for Eaton 9355

  • Page 1 Eaton 9355 UPS ® 20/30 kVA Installation and Operation Manual..
  • Page 3 Eaton 9355 UPS ® 20/30 kVA Installation and Operation Manual..
  • Page 4 Eaton, Powerware, ABM, LanSafe, Powerware Hot Sync, and X-Slot are registered trademarks of Eaton or its subsidiaries and affiliates. Greenlee is a registered trademark of Greenlee Textron. Modbus is a registered trademark of Schneider Automation. National Electrical Code and NEC are registered trademarks of National Fire Protection Association, Inc.
  • Page 5 Class A EMC Statements FCC Part 15 This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 6: Special Symbols

    Special Symbols The following are examples of symbols used on the UPS or accessories to alert you to important information: RISK OF ELECTRIC SHOCK - Observe the warning associated with the risk of electric shock symbol. CAUTION: REFER TO OPERATOR'S MANUAL - Refer to your operator's manual for additional information, such as important operating and maintenance instructions.
  • Page 7: Table Of Contents

    PARALLEL COMMUNICATION........Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F..
  • Page 8 Limited Factory Warranty .......Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F..
  • Page 9: Introduction

    During brownouts, blackouts, and other power interruptions, batteries provide emergency power to safeguard operation. With the Eaton 9355 UPS, you can safely eliminate the effects of electrical line disturbances and guard the integrity of your systems and equipment. Figure 1 shows the Eaton 9355 UPS (20/30 kVA) with an optional Extended Battery Cabinet (EBC) and Options Cabinet.
  • Page 10 Introduction Providing outstanding performance and reliability, the Eaton 9355 UPS's unique benefits including the following: Online UPS design with pure sine wave output. The UPS filters and regulates incoming AC power and provides consistent power to your equipment without draining the battery.
  • Page 11 UPS from virtually any location within the facility. You can install multiple RMPs at remote locations to increase your monitoring capabilities. Seismic Kit The optional seismic kit secures the UPS and optional cabinets for Zone 4 seismic installations. Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 12 Introduction This page intentionally left blank. Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 13: Safety Warnings

    Keep unauthorized personnel away from batteries. Proper disposal of batteries is required. Refer to your local codes for disposal requirements. Never dispose of batteries in a fire. Batteries may explode when exposed to flame. Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 14 Une mise au rebut réglementaire des batteries est obligatoire. Consulter les règlements en vigueur dans votre localité. Ne jamais jeter les batteries au feu. L'exposition aux flammes risque de les faire exploser. Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 15 Es necesario desechar las baterías de un modo adecuado. Consulte las normas locales para conocer los requisitos pertinentes. Nunca deseche las baterías en el fuego. Las baterías pueden explotar si se las expone a la llama. Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 16 Safety Warnings This page intentionally left blank. Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 17: Ups Setup

    Options Cabinet with MBS only 205 lb (93 kg) 51 lb/in (3.6 kg/cm Clearances The following clearances are recommended for the Eaton 9355 UPS: From Front of Cabinet 36' (91.4 cm) working space From Back of Cabinet 6' (15.2 cm) From Right of Cabinet Refer to local codes for right side service access [minimum 36'..
  • Page 18: Removing And Replacing The Front Doors

    Lift the door up and off the cabinet. To replace the door: Insert the door notches into the slots on the bottom of the cabinet. Secure the door latches. Figure 2. Removing the UPS Front Door Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 19: Ebc Front Door

    Lift the door up and off the cabinet. To replace the door: Place the door on the bottom hooks of the EBC. Replace the two door screws. Figure 3. Removing the EBC Front Door Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 20: Unloading The Cabinet(s)

    Be sure to retain the rear shipping bracket and hardware for later re-assembly if you plan to permanently mount the cabinet. M10 Bolts M8 Screws Figure 4. Removing the Rear Shipping Bracket (UPS Shown) Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 21 Remove the three M10 bolts securing the rear shipping pad to the pallet and remove the shipping pad (see Figure 5). M10 Bolts Shipping Pad Figure 5. Removing the Shipping Pad (UPS Shown) Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 22 Remove the two M10 bolts securing the front shipping bracket to the pallet and remove the bracket. M10 Bolts M8 Screws Figure 6. Removing the Front Shipping Bracket (UPS Shown) Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 23 Slowly roll the cabinet toward the rear of the pallet. Once the pallet tilts, continue rolling the cabinet down the pallet until the cabinet touches the floor (see Figure 8). Figure 8. Unloading the Cabinet (UPS Shown) Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 24 11. Roll the cabinet to the desired location. 12. If you are installing more than one cabinet, continue to “Joining the Cabinets” on page 17; otherwise, continue to “Electrical Installation” on page 21. Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 25: Joining The Cabinets

    If you have two Options Cabinets, remove the three circular knockouts on the left side of the first Options Cabinet. 10. Install three bushings (supplied) in the circular knockouts of the adjacent cabinet. Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 26 13. Install the other ground strap between the front panels of the adjacent cabinets as shown in Figure 11. 14. Repeat Steps 11 through 13 for each cabinet. 15. Replace the front door of all cabinets. 16. Continue to “Electrical Installation” on page 21. Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 27 Joining the Cabinets Rear Ground Strap Front Ground Strap Figure 11. Ground Strap Installation Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 28 Joining the Cabinets This page intentionally left blank. Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 29: Electrical Installation

    To accommodate the feature of easy system expandability, it is recommended that initial installation of the Eaton 9355 UPS contain wiring to support the maximum capacity of the UPS cabinet. Switch off utility power to the distribution point where the UPS or Options Cabinet will be connected. Be absolutely sure there is no power.
  • Page 30 Electrical Installation Input Circuit Output Circuit Battery Circuit Breaker Breaker (optional) Breaker Wiring Access Cover UPS Connection Insulator Figure 12. UPS Front View Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 31: Wiring Installation

    UPS with Options Cabinet that has an input transformer only – see “Options Cabinet with Dual-Feed Wiring” on page 31 UPS with Options Cabinet that has an output transformer only– see “Options Cabinet with Output Transformer Wiring” on 33 Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 32: Ups Only Wiring

    Reinstall the UPS conduit landing box in the reversed position (see Figure 14). Replace the UPS front door (see page 10). Figure 14. Reversing the UPS Conduit Landing Box Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 33: Parallel Ups Wiring

    From UPS 1 Output From UPS 2 Output From UPS 3 Output From UPS 4 Output Figure 15. Parallel Wiring Diagram – Version 1 and Version 2 without Maitenance Isolation Switch (MIS) Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 34 13. Reinstall the UPS wiring access cover. 14. Reinstall the UPS conduit landing box in the reversed position (see Figure 14 on page 24). 15. Replace the UPS front door (see page 10). Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 35 Electrical Installation Maintenance Bypass Wiring to UPS TB4 Neutral Ground Line 1 Line 3 Line 2 Figure 17. Bypass AC Input Wiring (Eaton Tie Cabinet Version 1 Shown) Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 36 Electrical Installation Neutral Ground Line 2 Line 3 Line 1 Maintenance Bypass Wiring to UPS TB4 Figure 18. Bypass AC Input Wiring (Eaton Tie Cabinet Version 2 with MIS Shown) Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 37: Options Cabinet With Mbs Wiring

    10. Reinstall the UPS connections insulator. 11. Reinstall the UPS wiring access cover. 12. Replace the UPS front door (see page 10). Figure 19. Reversing the Options Cabinet Conduit Landing Box Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 38 Options Cabinet with Bypass Auxiliary MBS and Input Isolation Contacts Transformer or with MBS and Input and Output Transformer L1 L1 Input Output Figure 20. Options Cabinet with MBS Wiring Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 39: Options Cabinet With Dual-feed Wiring

    10. Replace both Options Cabinet front doors (see page 10). 11. Reinstall the UPS connections insulator. 12. Reinstall the UPS wiring access cover. 13. Replace the UPS front door (see page 10). Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 40 Second Options Cabinet First Options Cabinet with Rectifier Transformer with MBS Only L1 L1 L1 L1 Input Input Output Maintenance Bypass Auxiliary Contacts Figure 21. Options Cabinets with Dual-Feed Wiring Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 41: Options Cabinet With Output Transformer Wiring

    Replace both Options Cabinet front doors (see page 10). 10. Reinstall the UPS connections insulator. 11. Reinstall the UPS wiring access cover. 12. Replace the UPS front door (see page 10). Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 42 Second Options Cabinet First Options Cabinet with Output Transformer with MBS Only L1 L1 Input Output Output Maintenance Bypass Auxiliary Contacts Figure 22. Options Cabinets with Output Transformer Wiring Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 43: Wiring Specifications And Diagrams

    Cabinet with an input isolation transformer, the input neutral is supplied by the input isolation transformer. Note: The Eaton 9355 UPS is shipped as a single-feed UPS and can be converted to a dual-feed UPS in the field. Note: DO NOT overtighten the screws; be sure to use the specified tightening torque values shown in Table 1.
  • Page 44 The two input neutral terminals are jumpered together; use either one of these terminals to make the input neutral connection. Note: The two output neutral terminals are jumpered together; use either one of these terminals to make the output neutral connection. Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 45 Electrical Installation Figure 24. UPS Wiring Diagram (Single-Feed, 208V or 220V Input : 208V or 220V Output) Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 46 Electrical Installation Figure 25. UPS with EBCs Wiring Diagram (Single-Feed, 208V or 220V Input : 208V or 220V Output) Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 47 Electrical Installation Figure 26. UPS and Options Cabinet with MBS Only (Single-Feed, 208V or 220V Input : 208V Output) Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 48 Electrical Installation Figure 27. UPS and Options Cabinet with MBS/Input Isolation Transformer Wiring Diagram (Single-Feed, 208V, 480V, or 600V Input : 208V Output) Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 49 Electrical Installation Figure 28. UPS and Dual-Feed Options Cabinets Wiring Diagram (Dual-Feed, 208V, 480V, or 600V Input : 208V Output) Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 50 Electrical Installation Figure 29. UPS and Dual Options Cabinets with Input and Output Transformers Wiring Diagram (Single-Feed, 480V Input : 480V Output) Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 51 Electrical Installation Figure 30. UPS and Single Options Cabinet with Input and Output Transformers Wiring Diagram (Single-Feed, 480V Input : 480V Output) Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 52 Electrical Installation Figure 31. Parallel UPS System with Tie Cabinet Diagram (Single-Feed, 208V or 220V Input : 208V or 220V Output) Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 53: Extended Battery Cabinet Installation

    “Operation” on page 69 to start up the UPS. Note: After UPS startup, ensure maximum battery runtime by configuring the UPS for the correct number of EBCs (see page 75). Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 54 Extended Battery Cabinet Installation UPS Battery Connector EBC Battery Connector EBC Cable UPS Battery Circuit Breaker Figure 32. Typical EBC Installation Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 55 Extended Battery Cabinet Installation EBC Cable Hooks Figure 33. Dual Transformer Options Cabinet EBC Cable Hooks Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 56 Extended Battery Cabinet Installation This page intentionally left blank. Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 57: Permanent Mounting Installation

    “Operation” on page 69 to start up the UPS. Note: After UPS startup, ensure maximum battery runtime by configuring the UPS for the correct number of EBCs (see page 75). Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 58 Permanent Mounting Installation Figure 35. Permanent Mounting Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 59: Communication

    REPO (normally open) REPO (normally closed) Signal Input 2 Pull-Chain Output Signal Input 1 Contacts (parallel only) DB-9 Communication Port Relay Output Contacts Figure 36. Communication Options and Control Terminals Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 60: Installing Communication Options And Control Terminals

    Route the control terminal cable(s) through the middle of the fan section and secure in the cable clips. Cable Clips for Control Terminal Wiring Figure 37. Installing Communication Cables Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 61 See “Communication Options” on page 54 or “Control Terminals” on page 60 for detailed information. Reinstall the communication wiring access plate. Replace the UPS front door. Continue to “Operation” on page 69 to start up the UPS. Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 62: Communication Options

    For information about the Powerware Hot Sync CAN Bridge Card, see ”Parallel Communication” on page 63. X-Slot cards allow the UPS to communicate in a variety of networking environments and with different types of devices. The Eaton 9355 UPS has two available communication bays for any X-Slot card, including: Power Xpert Gateway Card - provides a data gateway from the UPS to the Power Xpert Software;..
  • Page 63 USB Card - connects to a USB port on your computer. Note: The Eaton 9355 UPS does not detect plug-and-play hardware. Before installing the USB Card, set the UPS baud rate to 1200 through the front panel (see Table 7 on page 70).
  • Page 64: Remote Monitor Panel

    Figure 42 shows an RMP. Figure 43 shows the enclosure dimensions and cable exit openings. Cable Exit Opening for 1/2” Conduit or Provided Strain Relief Horn Silence Button Figure 42. Remote Monitor Panel Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 65 Connect the wiring between the RMP and the IRC plug-in terminal blocks using terminations shown in Table 3. See Figure 44 and Figure 45 for plug-in terminal block locations. Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 66 NOTE Conduit and wiring supplied by the customer. The maximum distance between the RMP and the UPS is not to exceed 500 ft (152.4m). Figure 44. RMP Top Internal View Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 67: Industrial Relay Card

    J2-4 Bypass mode J2-5 J2-6 J2-7 Battery mode J2-8 J2-9 J2-10 Alarm mode J2-11 J2-12 NOTE Maximum contact rating: 250 Vac, 30 Vdc @ 5A; Wire range: 16–24 AWG Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 68: Lansafe Power Management Software

    UPS or power information. If there is a power outage and the Eaton 9355 UPS battery power becomes low, LanSafe software can automatically shut down your computer system to protect your data before the UPS shutdown occurs.
  • Page 69: Remote Emergency Power-off

    The pins must be shorted with maximum resistance of 10 ohm to activate the specific input. Note: See Figure 46 on page 60 for the polarity and verify these connections if polarity control is required. Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 70 If active, the UPS knows that input is fed from the generator. Bypass is disabled; the automatic battery test is disabled. External Transformer Overtemperature This option is not used. Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 71: Parallel Communication

    Remove the communication wiring access plate from the UPS rear panel and punch a hole in it using a Greenlee punch or similar device (see Figure 48). Install conduit for the communication wiring. Communication Wiring Access Plate Figure 48. Communication Wiring Access Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 72 Route the wiring through the conduit from the communication wiring access plate to the opening between the two X-Slot communication bays on each UPS (see Figure 50). Figure 50. Routing the Cables Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 73 10. Route the pull-chain wiring through the middle of the fan section and secure in the cable clips for each UPS (see Figure 51). Figure 51. Installing Communication Cables Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 74 Signal Input 2 can still be used for building alarms; it is automatically rerouted to the CAN Bridge Card. 12. Reinstall the communication wiring access plate on each UPS. 13. Replace the UPS front door on each UPS. Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 75 X52- - NC UPS #1 UPS #2 UPS #3 From UPS #1 To UPS #3 Signal Input 2 Pull-Chain Output Contacts Figure 52. CAN Bridge Card and Pull-Chain Wiring Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 76 Parallel Communication This page intentionally left blank. Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 77: Operation

    Chapter 10 Operation This chapter contains information on how to use the Eaton 9355 UPS, including front panel operation, UPS startup and shutdown, and configuring the UPS for Extended Battery Cabinets (EBCs). Control Panel Functions The UPS has a four-button graphical LCD with backlight. It provides useful information about the UPS itself, load status, events, measurements, and settings (see Figure 53).
  • Page 78: User Settings

    Alarm 1: empty Setup: [Battery Low] [On Battery] [On Bypass] [UPS ok] X-Slots (1 or 2) [custom] [empty] #1: UPS ok #2: On Bypass #3: Summary Alarm #4: On Battery Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 79 Control Commands from X-Slot1 Allowed/Disabled Allowed Control Commands from X-Slot2/ Allowed/Disabled Allowed Serv X-Slot Signal Input Activation Delay 0 through 65 seconds Input Signal Delayed Shutdown 1 through 65535 seconds 120s Delay Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 80: Initial Startup

    Disabled after initial startup Initial Startup Startup and operational checks must be performed by an authorized Eaton Customer Service Engineer, or the warranty terms as specified on page 89 become void. This service is offered as part of the sales contract for the UPS.
  • Page 81: Starting The Ups On Battery

    Press any button on the front panel display to activate the menu options. Within three minutes, press the button on the front panel display and then press the button to select the TURN UPS ON/OFF menu. Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 82: Internal Bypass Startup

    Switch on utility power where the UPS is connected. The load is now powered by utility power. To transfer the load to the UPS, see “Using the UPS Maintenance Bypass Switch” on page 80. Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 83: Configuring The Ups For Ebcs

    If the optional UPS output circuit breaker is installed, switch the breaker to the OFF position. Replace the UPS front door. Switch off utility power where the UPS is connected. Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 84: Parallel Operation

    Operation Parallel Operation Initial startup must be performed by an authorized Eaton Customer Service Engineer. This section describes shutting down and restarting UPSs in a parallel system. Parallel System Shutdown To remove power to the parallel UPS system output: Press any button on the front panel display to activate the menu options.
  • Page 85: Restarting The Parallel System

    The UPS goes to Bypass mode for five seconds, and then the indicator illuminates. Each UPS should be in Normal mode. 14. Press the button until the Eaton logo or Mimic screen appears. Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 86 Operation This page intentionally left blank. Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 87: Ups Maintenance

    Change the batteries approximately every five years. Recycling the Used Battery or UPS Contact your local recycling or hazardous waste center for information on proper disposal of the used battery or UPS. Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 88: Using The Ups Maintenance Bypass Switch

    The SERVICE position on the switch allows a service engineer to apply power to the UPS input and verify its operation while the load is powered through bypass. Figure 55. Maintenance Bypass Switch Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 89: Single Ups Bypass

    Turn the maintenance bypass switch to the UPS position to return to Normal mode. Verify the rear fan is running. The UPS is now powering the load. Replace the UPS front door. Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 90: Parallel Ups Bypass

    On the same UPS front panel, set the UPS to Normal mode: Press the button to select the Go to Normal Mode option. Each UPS should go to Normal mode. The UPS is now powering the load in Normal mode. Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 91: Specifications

    <62 dBA Surge Suppression ANSI C62.41 Category B3 Safety Conformance NOM-019-SCFI, UL 1778, CSA C22.2, No. 107.3 Agency Markings cULus EMC (Class A) IEC 62040-2, FCC Part 15, ICES-003 Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 92 Output Frequency 50/60-Hz selectable or autoconfiguring Output Frequency Regulation Synchronization to line Output Overload 101–110% for 10 minutes 111–125% for 60 seconds 126–149% for 5 seconds >150% for 300 milliseconds Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 93 100A 100A 100A Output Current Output kVA Output kW Efficiency (Minimum) Heat Rejection [BTU/hr (kg-cal/hr)] 9220 (2323) 13831 (3485) 13831 (3485) 9220 (2323) 13493 (3402) 18104 (4565) 18104 (4565) Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 94 +(1) EBC 72 +(2) EBC 72 +(3) EBC 72 30 kVA/27 kW 20 kVA/18 kW NOTE Battery times are approximate and vary depending on the load configuration and battery charge. Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 95: Troubleshooting

    Chapter 13 Troubleshooting The Eaton 9355 is designed for durable, automatic operation and also alerts you whenever potential operating problems may occur. Usually the alarms shown by the control panel do not mean that the output power is affected. Instead, they are preventive alarms intended to alert the user. Use the following troubleshooting chart to determine the UPS alarm condition.
  • Page 96: Silencing The Alarm

    Please have the following information ready when you call for service: Model number Serial number Firmware version number Date of failure or problem Symptoms of failure or problem Customer return address and contact information Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality..
  • Page 97: Warranty

    “Warranted Items”) are free from defects in material and workmanship. If, in the opinion of Eaton, a Warranted Item is defective and the defect is within the terms of this Warranty, Eaton's sole obligation will be to repair or replace such defective item (including by providing service, parts, and labor, as applicable), at the option of Eaton.
  • Page 98 OTHER LIMITATIONS: Eaton's obligations under this Warranty are expressly conditioned upon receipt by Eaton of all payments due to it (including interest charges, if any). During such time as Eaton has not received payment of any amount due to it for the Product, in accordance with the contract terms under which the Product is sold, Eaton shall have no obligation under this Warranty.
  • Page 100 *164201626 D* 164201626 F..
Also See for Powerware 9355
User manual - 120 pages
Installation and operation manual - 100 pages
Installation manual - 36 pages
123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100
®
Installation and Operation Manual

Advertisement

It created with the purpose is to share free games for all of you. To a new website, it does not have much your attention, but I wish you could give me a favour in advertising, introducing it to people by sharing its link for your friends, family members through out Facebook, twitter and other websites. At the present, more than 3000 free games are loaded on the website and it has still been in process of building, finishing the contents, so I hope that most of free games could be updated as soon as possible. Gundam extreme vs full boost download.

Also See for Eaton Powerware 9355

Eaton E.T.N 1500 VA - 60kVa Reference Manual120 pages

Related Manuals for Eaton Powerware 9355

  • UPS Eaton 9355 User Manual
    10/15 kva (90 pages)
  • UPS Eaton 9355 User Manual
    Powerware series parallel ups 10/15 kva (78 pages)
  • UPS Eaton UPS 20 User Manual
    Ups 20 - 40 kva, 230/400 v 50/60 hz output (3-phase input/output) (56 pages)
  • UPS Eaton 9355 Installation Manual
    Powerware series tie cabinet for use with eaton 9355 20/30 kva upss (36 pages)
  • UPS Eaton Eaton series Instructions Manual
    Battery upgrade instructions (14 pages)
  • UPS Eaton 9390 Brochure & Specs
    20-160 kva (20 pages)
  • UPS Eaton 9390 Installation And Operation Manual
    40–80 kva ups, integrated distribution cabinet (100 pages)

Summary of Contents for Eaton Powerware 9355

  • Page 1 Powerware 9355 UPS ® 20/30 kVA Installation and Operation Manual..
  • Page 2 Quality Corporation. Greenlee is a registered trademark of Greenlee Textron. Modbus is a registered trademark of Modicon. ECopyright 2006 Eaton Corporation, Raleigh, NC, USA. All rights reserved. No part of this document may be reproduced in any way without the..
  • Page 3 89/336/EEC, Council Directive relating to electromagnetic compatibility 92/31/EEC, Amending Directive 89/336/EEC relating to EMC The EC Declaration of Conformity is available upon request for products with a CE mark. For copies of the EC Declaration of Conformity, contact: Eaton Power Quality Oy Koskelontie 13 FIN-02920 Espoo..
  • Page 4: Special Symbols

    Special Symbols The following are examples of symbols used on the UPS or accessories to alert you to important information: RISK OF ELECTRIC SHOCK - Indicates that a risk of electric shock is present and the associated warning should be observed. CAUTION: REFER TO OPERATOR’S MANUAL - Refer to your operator’s manual for additional information, such as important operating and maintenance instructions.
  • Page 5: Table Of Contents

    ........ ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual..
  • Page 6 ...... . ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual..
  • Page 7: Introduction

    During brownouts, blackouts, and other power interruptions, batteries provide emergency power to safeguard operation. With the Powerware 9355 UPS, you can safely eliminate the effects of electrical line disturbances and guard the integrity of your systems and equipment. Figure 1 shows the Powerware 9355 UPS (20/30 kVA) with an optional Extended Battery Cabinet (EBC) and Options Cabinet.
  • Page 8 INTRODUCTION Providing outstanding performance and reliability, the Powerware 9355 UPS’s unique benefits including the following: Online UPS design with pure sine wave output. The UPS filters and regulates incoming AC power and provides consistent power to your equipment without draining the battery.
  • Page 9 RMPs at remote locations to increase your monitoring capabilities. Seismic Kit The optional seismic kit secures the UPS and optional cabinets for Zone 4 seismic installations. ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 10 INTRODUCTION ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 11: Safety Warnings

    Proper disposal of batteries is required. Refer to your local codes for disposal requirements. Never dispose of batteries in a fire. Batteries may explode when exposed to flame. ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 12 Une mise au rebut réglementaire des batteries est obligatoire. Consulter les règlements en vigueur dans votre localité. Ne jamais jeter les batteries au feu. L’exposition aux flammes risque de les faire exploser. ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 13: Advertencias De Seguridad

    Es necesario desechar las baterías de un modo adecuado. Consulte las normas locales para conocer los requisitos pertinentes. Nunca deseche las baterías en el fuego. Las baterías pueden explotar si se las expone a la llama. ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 14 SAFETY WARNINGS ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 15: Ups Setup

    Options Cabinet with MBS only 205 lb (93 kg) 51 lb/in (3.6 kg/cm Clearances The following clearances are recommended for the Powerware 9355 UPS: From Front of Cabinet 36” (91.4 cm) working space From Back of Cabinet 6” (15.2 cm) From Right of Cabinet Refer to local codes for right side service access [minimum 24”..
  • Page 16: Removing And Replacing The Front Doors

    To replace the door: Insert the door notches into the slots on the bottom of the cabinet. Secure the door latches. Figure 2. Removing the UPS Front Door ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 17: Ebc Front Door

    To replace the door: Place the door on the bottom hooks of the EBC. Replace the two door screws. Figure 3. Removing the EBC Front Door ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 18: Unloading The Cabinet(s)

    NOTE Be sure to retain the rear shipping bracket and hardware for later re-assembly if you plan to permanently mount the cabinet. M10 Bolts M8 Screws Figure 4. Removing the Rear Shipping Bracket (UPS Shown) ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 19 Remove the three M10 bolts securing the rear shipping pad to the pallet and remove the shipping pad (see Figure 5). M10 Bolts Shipping Pad Figure 5. Removing the Shipping Pad (UPS Shown) ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 20 Remove the two M10 bolts securing the front shipping bracket to the pallet and remove the bracket. M10 Bolts M8 Screws Figure 6. Removing the Front Shipping Bracket (UPS Shown) Replace the front door. ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 21 Slowly roll the cabinet toward the rear of the pallet. Once the pallet tilts, continue rolling the cabinet down the pallet until the cabinet touches the floor (see Figure 8). Figure 8. Unloading the Cabinet (UPS Shown) ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 22 12. If you are installing more than one cabinet, continue to “Joining the Cabinets” on page 17; otherwise, continue to “Electrical Installation” on page 21. ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 23: Joining The Cabinets

    If you have two Options Cabinets, remove the three circular knockouts on the left side of the first Options Cabinet. 10. Install three bushings (supplied) in the circular knockouts of the adjacent cabinet. ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 24 14. Repeat Steps 11 through 13 for each cabinet. 15. Replace the front door of all cabinets. 16. Continue to “Electrical Installation” on page 21. ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 25 JOINING THE CABINETS Rear Ground Strap Front Ground Strap Figure 11. Ground Strap Installation ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 26 JOINING THE CABINETS ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 27: Electrical Installation

    NOTE To accommodate the feature of easy system expandability, it is recommended that initial installation of the Powerware 9355 UPS contain wiring to support the maximum capacity of the UPS cabinet. Switch off utility power to the distribution point where the UPS or Options Cabinet will be connected.
  • Page 28 ELECTRICAL INSTALLATION Input Circuit Output Circuit Battery Circuit Breaker Breaker (optional) Breaker Wiring Access Cover Figure 12. UPS Front View ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 29 12. If you have two Options Cabinets, repeat Steps 10 and 11 for the second cabinet. Figure 13. Removing the Options Cabinet Wiring Access Cover ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 30: Wiring Installation

    Cabinet with Dual-Feed Wiring” on page 30 UPS with Options Cabinet that has an output transformer — see “Options Cabinet with Output Transformer Wiring” on page 32 ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 31: Ups Only Wiring

    Reinstall the UPS conduit landing box in the reversed position (see Figure 14). Replace the UPS front door (see page 10). Figure 14. Reversing the UPS Conduit Landing Box ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 32: Parallel Ups Wiring

    Bypass Input 110A (4X) LOAD From UPS 1 Output From UPS 2 Output From UPS 3 Output From UPS 4 Output Figure 15. Parallel Wiring Diagram ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 33 13. Reinstall the UPS conduit landing box in the reversed position (see Figure 14 on page 25). 14. Replace the UPS front door (see page 10). ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 34: Options Cabinet With Mbs Wiring

    10. Reinstall the UPS wiring access cover. 11. Replace the UPS front door (see page 10). Figure 17. Reversing the Options Cabinet Conduit Landing Box ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 35 Input Output Maintenance Options Cabinet with Bypass Auxiliary MBS and Input Contacts Isolation Transformer L1 L1 Input Output Figure 18. Options Cabinet with MBS Wiring ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 36: Options Cabinet With Dual-feed Wiring

    10. Replace both Options Cabinet front doors (see page 10). 11. Reinstall the UPS wiring access cover. 12. Replace the UPS front door (see page 10). ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 37 First Options Cabinet with Rectifier Transformer with MBS Only L1 L1 L1 L1 Input Input Output Maintenance Bypass Auxiliary Contacts Figure 19. Options Cabinets with Dual-Feed Wiring ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 38: Options Cabinet With Output Transformer Wiring

    Replace both Options Cabinet front doors (see page 10). 10. Reinstall the UPS wiring access cover. 11. Replace the UPS front door (see page 10). ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 39 First Options Cabinet with Output Transformer with MBS Only L1 L1 Input Output Output Maintenance Bypass Auxiliary Contacts Figure 20. Options Cabinets with Output Transformer Wiring ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 40: Wiring Specifications And Diagrams

    NOTE Input neutral must be wired for proper operation or the UPS will not start. If you have an Options Cabinet with an input isolation transformer, the input neutral is supplied by the input isolation transformer. NOTE The Powerware 9355 UPS is shipped as a single-feed UPS and can be converted to a dual-feed UPS in the field.
  • Page 41 NOTE The two output neutral terminals are jumpered together; use either one of these terminals to make the output neutral connection. ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 42 ELECTRICAL INSTALLATION Figure 22. UPS Wiring Diagram (Single-Feed, 208V or 220V Input : 208V or 220V Output) ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 43 ELECTRICAL INSTALLATION Figure 23. UPS with EBCs Wiring Diagram (Single-Feed, 208V or 220V Input : 208V or 220V Output) ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 44 ELECTRICAL INSTALLATION Figure 24. UPS and Options Cabinet with MBS Only (Single-Feed, 208V or 220V Input : 208V Output) ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 45 ELECTRICAL INSTALLATION Figure 25. UPS and Options Cabinet with MBS/Input Isolation Transformer Wiring Diagram (Single-Feed, 208V, 480V, or 600V Input : 208V Output) ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 46 ELECTRICAL INSTALLATION Figure 26. UPS and Dual-Feed Options Cabinets Wiring Diagram (Dual-Feed, 208V, 480V, or 600V Input : 208V Output) ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 47 ELECTRICAL INSTALLATION Figure 27. UPS and Options Cabinet with Output Transformer Wiring Diagram (Single-Feed, 480V Input : 480V Output) ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 48 ELECTRICAL INSTALLATION Figure 28. Parallel UPS System with Tie Cabinet Diagram (Single-Feed, 208V or 220V Input : 208V or 220V Output) ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 49: Extended Battery Cabinet Installation

    “Operation” on page 67 to start up the UPS. NOTE After UPS startup, ensure maximum battery runtime by configuring the UPS for the correct number of EBCs (see page 74). ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 50 EXTENDED BATTERY CABINET INSTALLATION UPS Battery Connector EBC Battery Connector EBC Cable UPS Battery Circuit Breaker Figure 29. Typical EBC Installation ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 51: Permanent Mounting Installation

    “Communication” on page 47 to install UPS communication options, such as X-Slot cards or remote emergency power-off (REPO). “Operation” on page 67 to start up the UPS. ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 52 PERMANENT MOUNTING INSTALLATION Figure 31. Permanent Mounting ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 53: Communication

    REPO (normally closed) Signal Input 2 Pull-Chain Output Signal Input 1 Contacts (parallel only) DB-9 Communication Port Relay Output Contacts Figure 32. Communication Options and Control Terminals ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 54: Installing Communication Options And Control Terminals

    Route the control terminal cable(s) through the middle of the fan section and secure in the cable clips. Cable Clips for Control Terminal Wiring Figure 33. Installing Communication Cables ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 55 Reinstall the communication wiring access plate. Replace the UPS front door. Continue to “Operation” on page 67 to start up the UPS. ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 56: Communication Options

    COMMUNICATION Communication Options The Powerware 9355 has serial communication capabilities through the DB-9 communication port or through an X-Slot card in one of the available bays. In addition, the Powerware LanSafe Power Management Software can be installed and used to communicate with the UPS via one of the serial communication connections.
  • Page 57: X-slot Cards

    USB Card - connects to a USB port on your computer. NOTE The Powerware 9355 does not detect plug-and-play hardware. Before installing the USB Card, set the UPS baud rate to 1200 through the front panel (see Table 7 on page 69).
  • Page 58: Remote Monitor Panel

    Figure 38 shows an RMP. Figure 39 shows the enclosure dimensions and cable exit openings. Cable Exit Opening for 1/2” Conduit or Provided Strain Relief Horn Silence Button Figure 38. Remote Monitor Panel ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 59 Connect the wiring between the RMP and the IRC plug-in terminal blocks using terminations shown in Table 3. See Figure 40 and Figure 41 for plug-in terminal block locations. ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 60 The maximum distance between the RMP and the UPS is not to exceed 500 ft (152.4m). Figure 40. RMP Top Internal View ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 61: Industrial Relay Card

    IRC still does not operate correctly, replace the fuse. If this does not correct the problem, contact your service representative for verification that the IRC is working correctly. ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 62: Powerware Lansafe Power Management Software

    UPS or power information. If there is a power outage and the Powerware 9355 UPS battery power becomes low, Powerware LanSafe software can automatically shut down your computer system to protect your data before the UPS shutdown occurs.
  • Page 63: Control Terminals

    UPS running. Maximum resistance is 10 ohm. NOTE Leave the REPO connector installed in the REPO port on the UPS even if the REPO function is not needed. ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 64: Relay Output Contacts

    The relay output contacts must not be connected to any utility connected circuits. Reinforced insulation to the utility is required. The relay output contacts have a maximum rating of 10A, 250 Vac or 30 Vdc nominal values. ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 65: Programmable Signal Inputs

    If active, the UPS knows that input is fed from the generator. Bypass is disabled; the automatic battery test is disabled. External Transformer Overtemperature This option is not used. ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 66 COMMUNICATION ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 67: Parallel Communication

    Greenlee punch or similar device (see Figure 44). Install conduit for the communication wiring. Communication Wiring Access Plate Figure 44. Communication Wiring Access ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 68 Strip shielded, four-wire, twisted-pair wire (maximum 18 AWG recommended) for CAN Bridge Card wiring and pull-chain wiring. Repeat Steps 1 through 6 for each UPS. ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 69 Step 11.) Be sure to check correct polarity for Pins 8 and 9: Connect SHIELD Pin 10 on all cards together. Connect CAN H Pin 9 and CAN L Pin 8 (twisted pair) on all cards together. ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 70 10. Route the pull-chain wiring through the middle of the fan section and secure in the cable clips for each UPS (see Figure 47). Figure 47. Installing Communication Cables ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 71 NOTE Signal Input 2 can still be used for building alarms; it is automatically rerouted to the CAN Bridge Card. 12. Reinstall the communication wiring access plate on each UPS. 13. Replace the UPS front door on each UPS. ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 72 UPS #1 UPS #2 UPS #3 From UPS #1 To UPS #3 Signal Input 2 Pull-Chain Output Contacts Figure 48. CAN Bridge Card and Pull-Chain Wiring ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 73: Operation

    Chapter 10 Operation This chapter contains information on how to use the Powerware 9355, including front panel operation, UPS startup and shutdown, and configuring the UPS for Extended Battery Cabinets (EBCs). Control Panel Functions The UPS has a four-button graphical LCD with backlight. It provides useful information about the UPS itself, load status, events, measurements, and settings (see Figure 49).
  • Page 74: Display Functions

    Display Functions As the default or after 15 minutes of inactivity, the LCD displays the selectable startup screen. The default is the Eaton Powerware logo and can be changed to the Mimic screen in the User Settings menu. The backlit LCD automatically dims after a long period of inactivity. Press any button to restore the screen.
  • Page 75: User Settings

    Automatic Battery Tests [Enabled/Disabled] Enabled Enabled automatically runs the battery test once a month. Full Power Battery Test [Enabled/Disabled] Enabled Start Screen Eaton Powerware logo Eaton Powerware logo Mimic screen ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual..
  • Page 76: Initial Startup

    Disabled after initial startup Initial Startup Startup and operational checks must be performed by an authorized Eaton Customer Service Engineer, or the warranty terms as specified on page 91 become void. This service is offered as part of the sales contract for the UPS. Contact service in advance (usually a two-week notice is required) to reserve a preferred startup date.
  • Page 77: Ups Startup

    UPS status from the front panel to view the active alarms. Correct the alarms and restart if necessary. 11. Replace the UPS front door. ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 78: Starting The Ups On Battery

    UPS stops beeping. The UPS starts in Battery mode within two minutes and supplies battery power to your equipment. Replace the UPS front door. ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 79: Internal Bypass Startup

    Press the button to select the Go To Normal Mode option. Press the button until the Eaton Powerware logo or Mimic screen appears. UPS Maintenance Bypass Startup To start the UPS in maintenance bypass: Remove the UPS front door (see page 10).
  • Page 80: Configuring The Ups For Ebcs

    3 EBC 72s Press the button to save the setting. Press the button until the Eaton Powerware logo or Mimic screen appears. UPS Shutdown To shut down the UPS: Press any button on the front panel display to activate the menu options.
  • Page 81: Parallel Operation

    OPERATION Parallel Operation Initial startup must be performed by an authorized Eaton Customer Service Engineer. This section describes shutting down and restarting UPSs in a parallel system. Parallel System Shutdown To remove power to the parallel UPS system output: Press any button on the front panel display to activate the menu options.
  • Page 82: Restarting The Parallel System

    The UPS goes to Bypass mode for five seconds, and then the indicator illuminates. Each UPS should be in Normal mode. 14. Press the button until the Eaton Powerware logo or Mimic screen appears. ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual..
  • Page 83: Ups Maintenance

    Check the battery recharge date on the shipping carton label. If the date has expired and the batteries were never recharged, do not use the UPS. Contact your service representative. ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 84: When To Replace Batteries

    C A U T I O N Do not discard waste electrical or electronic equipment (WEEE) in the trash. For proper disposal, contact your local recycling/reuse or hazardous waste center. ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 85: Using The Ups Maintenance Bypass Switch

    The SERVICE position on the switch allows a service engineer to apply power to the UPS input and verify its operation while the load is powered through bypass. Figure 51. Maintenance Bypass Switch ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 86: Single Ups Bypass

    Turn the maintenance bypass switch to the UPS position to return to Normal mode. The UPS is now powering the load. Replace the UPS front door. ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 87: Parallel Ups Bypass

    On the same UPS front panel, set the UPS to Normal mode: Press the button to select the Go to Normal Mode option. Each UPS should go to Normal mode. ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 88 UPS MAINTENANCE ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 89: Specifications

    Description (EBC) EBC 36 EBC with 2 strings EBC 72 EBC with 4 strings Table 9. Dimensions and Weights × × Powerware 9355 Cabinet Weight Dimensions (H Including Conduit Landing Box × × × × 1160 lb (526 kg) 66.3”..
  • Page 90 50/60-Hz selectable or auto-configuring Output Frequency Regulation Synchronization to line Output Overload 101–110% for 10 minutes 111–125% for 60 seconds 126–149% for 5 seconds >150% for 300 milliseconds ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 91 ABM technology increases battery service life, optimizes recharge time, and provides a warning before the end of useful battery life Protection EBC output protected by 200A circuit breaker ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 92 +(3) EBC 72 Batteries 30 kVA/27 kW 20 kVA/18 kW NOTE Battery times are approximate and vary depending on the load configuration and battery charge. ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 93: Troubleshooting

    Chapter 13 Troubleshooting The Powerware 9355 is designed for durable, automatic operation and also alerts you whenever potential operating problems may occur. Usually the alarms shown by the control panel do not mean that the output power is affected. Instead, they are preventive alarms intended to alert the user.
  • Page 94: Silencing The Alarm

    Press any button on the front panel display to silence the alarm. If the alarm status changes, the alarm beeps again, overriding the previous alarm silencing. ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 95: Service And Support

    Please have the following information ready when you call for service: Model number Serial number Firmware version number Date of failure or problem Symptoms of failure or problem Customer return address and contact information ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 96 TROUBLESHOOTING ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 97: Limited Warranty

    Powerware-built battery cabinets, (individually and collectively, the “Warranted Items”) are free from defects in material and workmanship. If, in the opinion of Eaton, a Warranted Item is defective and the defect is within the terms of this Warranty, Eaton’s sole obligation will be to repair or replace such defective item (including by providing service, parts and labor, as applicable), at the option of Eaton.
  • Page 98 LIMITED WARRANTY ® EATON Powerware 9355 UPS (20/30 kVA) Installation and Operation Manual 164201626 Rev B www.powerware.com..
  • Page 100 *164201626B* 164201626 B..
Posted :